  • 產(chǎn)品名稱(chēng):FMG813電磁流量計(jì) 美國(guó)omega

  • 產(chǎn)品型號(hào):FMG813電磁流量計(jì) 美國(guó)o
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車(chē)
簡(jiǎn)單介紹:
FMG813電磁流量計(jì) 美國(guó)omega由美國(guó)omega原廠渠道的深圳鑫博恒業(yè)科技有限公司特價(jià)提供,FMG813電磁流量計(jì) 美國(guó)omega精度高,壽命長(zhǎng),FMG813電磁流量計(jì) 美國(guó)omega是值得信賴(lài)的流量?jī)x表。
詳情介紹:

FMG813電磁流量計(jì) 美國(guó)omega

塑料體電磁流量計(jì)
FMG800 Series
1年保修 新產(chǎn)品!
塑料體電磁流量計(jì)
FMG800 系列:塑料體電磁流量計(jì)
沒(méi)有移動(dòng)部件
*小直管段的要求
電池供電的
內(nèi)置的速度和總指標(biāo)
耐腐蝕
脈沖輸出(fmg810只)
美國(guó)加侖的預(yù)編程
(其他單位提供)
The FMG800 Series is a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 1, 2 and 3 inch pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals and fertilizers. It is light weight and easy to install or remove from the pipe for inspection*.
With no moving parts, the magmeter permits unobstructed flow, minimizing flow disturbances and straight pipe requirements. The FMG800 Series can be used in piping configurations where there is little space between the meter and an elbow or valve. The FMG800 Series is resistant to wear from sand and debris found in ground or surface water. Since there are no bearings or propeller to wear out, maintenance and repair costs are kept to a minimum and it tolerates high flows without damage. A hinged polyethylene cover is included that protects from dust and UV rays, while permitting easy access to the flow rate and total display. Flow rate and total can be displayed in a variety of units, but must be factory programmed.
The FMG800 Series is used for tracking flow rate and total flow in usage monitoring applications including wells, industrial wastewater, heap leach mining discharge, cooling tower deduct, turf, landscape, and other water reclamation applications. In the event of DC power loss, or when changing batteries, the FMG800 will retain internal settings and flow total.
FMG800 Series The FMG810 Series is externally powered via a 5-pin connector cable which also provides pulse output for use with a variety of Omega displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications.
The FMG800 Series is a battery-operated unit for use when pulse output is not required. The batteries are user replaceable with an approximate 1 to 2 year life depending on usage.
*Includes Omega NPT fitting kit on 2 and 3" models.
Specifications
Pipe Size: 1, 2 or 3" full port
Fittings: 1 NPTF, 2 or 3" flange clamps with 2 or 3 NPTF fitting kit
Metric (BSP) fittings optional
Pressure: 150 psi or 10.3 bar working pressure @ 21°C (70°F)
Operating Temperature Range: -12 to 54°C (10 to 130°F), -40 to 80°C (-40 to 176°F) non-operating
Accuracy: ±1% of reading (between 10% and 100% of max flow) ±3% of reading (between cutoff and 10% of max flow)
Flow Range Minimum:
1": 2.3 GPM (0.145 LPS)
2": 6 GPM (0.38 LPS)
3": 14 GPM (0.88 LPS)
Flow Range Maximum:
1": 110 GPM (6.94 LPS)
2": 300 GPM (18.9 LPS)
3": 670 GPM (42.3 LPS)
Materials Body: Glass-filled polypropylene
Electrodes: 316 stainless steel
Electronics Housing: Die-cast aluminum, powder-coated
Display Cover: Polyethylene
Display Digits: Rate-6, Total-8
Units Rate: Gallons/Minute, Cubic Feet/ Second, Acre-Feet, Acre-Inch, Gallons, Gallons x 1000, Cubic Feet/Minute, Liters/Second
Units total: Cubic Feet, Liters, Mega-liters, Cubic Metersm Liters/Minute, Cubic Meters/Minute
Power:
FMG800: 10 to 30 Vdc @ 60 mA max (15 mA average)
NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation
FMG810: 6 each “AA” alkaline cells (included), replaceable. Estimated life is 1 to 2 years depending on usage
Pulse Output (FMG810 Only):
Signal: Current sinking pulse, opto-isolated, 32 Vdc max at 10 mA max
Standard Pulse Rate: 1 unit/pulse out, pulse width of 10 ms depending on unit selection
High Frequency (-HF): Pulse width 1.1 ms, min/max frequency, 3 to 150 hz
Pulse/Unit: 1" = 80, 2" = 30, 3" = 13
Empty Pipe Detection: Hardware/ software, conductivity-based
Conductivity: >20 micro Siemens/cm
Environmental: NEMA 4X standard
Electrical Connection (FMG810 Only): 5-pin male circular with 6 m (20') cable


產(chǎn)品型號(hào) 產(chǎn)品描述
FMG801 1' battery powered magmeter
FMG802 2' battery powered magmeter
FMG803 3' battery powered magmeter
FMG811 1' DC powered magmeter
FMG812 2' DC powered magmeter
FMG813 3' DC powered magmeter
FMG811-HF 1' DC powered magmeter high frequency out
FMG812-HF 2' DC powered magmeter high frequency out
FMG813-HF 3' DC powered magmeter high frequency out
 

注釋: Comes complete with operator’s manual.
2" units also include 5-pin 6 m (20') cable and 2 NPT fitting kit.
3" units also include 5-pin 6 cm (20') cable and 3 NPT fitting kit.
Battery powered units come complete with 6 "AA" batteries.
For metric fittings add suffix, "-BSP" to the model number, no additional cost.

 FMG813電磁流量計(jì) 美國(guó)omega 

標(biāo)題:
內(nèi)容:
聯(lián)系人:
聯(lián)系電話:
Email:
公司名稱(chēng):
聯(lián)系地址:
 
 
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!

粵公網(wǎng)安備 44030402001379號(hào)

主站蜘蛛池模板: 欧美一区2区 | 色悠久久久久综合欧美99 | 亚洲免费在线视频观看 | 一本伊人 | 五月天婷婷色综合 | 四月天中文字幕 | 日本a视频 | 三级在线观看免播放网站 | 欧美又肥又胖的大bbwⅹ | 性荡视频播放器在线视频播放 | 一区二区三区在线视频观看 | 在线观看亚洲天堂 | 亚洲欧美日韩不卡一区二区三区 | 欧美亚洲综合在线 | 小视频福利 | 天堂网2021天堂手机版丶 | 婷婷色伊人 | 日韩欧美专区 | 日韩高清的天堂在线观看免费 | 欧美做a一级视频免费观看 欧美坐爱视频 | 日本一区二区三 | 伊人国产在线视频 | 天堂在线最新版www中文 | 青娱乐免费视频观看 | 日本尤物精品视频在线看 | 色婷婷伊人 | 日韩最新中文字幕 | 欧美又黄又嫩大片a级 | 日日做夜夜爽夜夜爽 | 婷婷综合亚洲 | 天天舔天天| 色综合天天综合网国产国产人 | 小明永久2015www永久免费观看 | 亚洲精品福利你懂 | 视色视频在线观看 | 日本不卡在线观看免费v | 亚洲精品青青草原avav久久qv | 一二三四手机在线观看视频播放 | 日日噜噜夜夜狠狠久久aⅴ 日日噜噜夜夜狠狠扒开双腿 | 一本一道波多野结衣一区二区 | 小明永久成人一区二区 |